Xi'anISG Pipeline Pump
Category:
Product Description
Product Overview
The ISG series single-stage, single-suction pipeline centrifugal pumps are developed by refining and enhancing the performance parameters of the original IS-type pumps. This innovative design successfully addresses several limitations inherent in the IS model during operation. Featuring high efficiency, energy savings, low noise levels, stable performance, and easy maintenance, the ISG series represents the ideal next-generation replacement for IS pumps. Additionally, depending on the specific temperature requirements, the series includes specialized versions such as hot-water pumps, high-temperature pumps, corrosion-resistant pumps, and oil pumps. All products are designed and manufactured according to the international ISO 2858 standard and meet the stringent quality criteria outlined in the national JB/T 53058-93R standard issued by China’s Ministry of Machinery. Notably, these pumps passed the rigorous inspection conducted by the Ministry’s management system certification process in 1993.
ISG Pipeline Pump is a vertical centrifugal pump designed for clean water and similar liquids. It features a compact in-line structure, high efficiency, low noise, and stable operation. The pump is easy to install directly in pipeline systems, reducing space and maintenance requirements. Made with high-quality cast iron or stainless steel components, it ensures corrosion resistance and long service life. ISG Pipeline Pump is widely used in water supply, HVAC systems, industrial circulation, and pressure boosting applications, providing reliable and continuous fluid transport performance.
The ISG Pipeline Pump is designed for efficient and stable fluid transportation in industrial and commercial pipeline systems. As a reliable Pipeline Pump, it features a vertical inline structure that saves installation space while ensuring smooth hydraulic performance. The pump is equipped with a high-efficiency impeller and precision-balanced rotor, which reduce vibration and improve energy efficiency. Its corrosion-resistant casing and high-quality mechanical seal ensure long service life and minimal leakage during operation. Manufactured with advanced CNC machining and strict quality control, each unit undergoes pressure testing and performance inspection to guarantee reliability. The ISG Pipeline Pump is widely used in water supply, HVAC systems, industrial circulation, and booster applications, providing consistent flow and dependable operation under various working conditions.
Uses
1. ISG vertical pipeline pumps are designed for conveying clean water and other liquids with physical and chemical properties similar to clean water. They are suitable for industrial and municipal water supply and drainage systems, boosting water pressure in high-rise buildings, providing irrigation for landscaping, ensuring fire protection through pressure boosting, enabling long-distance water transportation, supporting HVAC and refrigeration circulation systems, and enhancing cold/hot water circulation in applications like bathrooms—along with being ideal for equipment integration. The operating temperature is capped at T < 80°C.
2. The IRG (GRG)-type vertical pipeline hot water (high-temperature) circulation pumps are widely suitable for applications including boilers in industries such as energy, metallurgy, chemical processing, textiles, papermaking, as well as hotels and restaurants—specifically for boosting, circulating, and delivering high-temperature hot water, and for use in urban heating systems. The IRG model is designed for operating temperatures up to T < 120°C, while the GRG model can handle temperatures up to T < 240°C.
3. The IHG vertical chemical process pump is designed for conveying liquids free of solid particles, which are corrosive and have a viscosity similar to water. It is suitable for industries such as petroleum, chemical processing, metallurgy, power generation, papermaking, food & pharmaceuticals, and synthetic fibers, with an operating temperature range of -20°C to 120°C.
4. The YG vertical pipeline oil pump is designed for conveying petroleum products such as gasoline, kerosene, and diesel fuel, with a medium temperature range of -20°C to +120°C.
Working conditions
1. The pump system’s maximum working pressure is 1.6 MPa, meaning the pump suction inlet pressure plus the pump head must not exceed 1.6 MPa. (If the pump system’s working pressure exceeds 1.6 MPa, please specify this requirement at the time of order so that special steel materials can be used for the pump’s flow passages and connecting components during manufacturing.)
2. The medium to be conveyed is clean water or other fluids with physicochemical properties similar to water. (If the medium contains fine particles, please specify separately at the time of ordering to enable the installation of a wear-resistant mechanical seal.)
3. Ambient temperature should not exceed 40°C, and relative humidity should remain below 95%.
Core structure
Vertical single-stage, single-suction design
Pump body: Features a vertical installation with inlet and outlet aligned on the same shaft, arranged at either 180° or 90° angles for easy pipeline connection.
Impeller: Designed as either closed or semi-open, with backward-curved blades that balance efficiency and cavitation resistance.
Pump shaft: Directly connected to the motor, made from stainless steel, offering high rigidity and minimal vibration.
Integrated motor and pump design
Direct-drive transmission: The motor shaft is directly connected to the pump shaft via a coupling, eliminating belt-drive losses and increasing efficiency by 5%–8% compared to conventional pumps.
Protection rating: Motor protection rating IP54/IP55, insulation class F, suitable for ambient temperatures ranging from -15°C to +40°C.
Sealing and Bearing System
Mechanical Seal: Features a silicon carbide/carbon-graphite friction pair, offering excellent wear and corrosion resistance, with a leakage rate of ≤0.5 mL/h.
Bearing configuration: The upper end features a deep-groove ball bearing (which handles radial loads), while the lower end is equipped with an angular contact bearing (designed to handle axial loads). Service life ≥ 20,000 hours.
Material Selection
Flow passage components: Available in cast iron (HT200), stainless steel (304/316L), copper alloys, and more, depending on the media characteristics.
Structural components: The pump housing is made of cast iron or stainless steel, while the motor casing features an aluminum alloy or cast iron exterior with a powder-coated finish.
Performance advantages
High-efficiency and energy-saving design
Hydraulic Model Optimization: CFD simulations are used to refine the flow passages, resulting in an efficiency improvement of 8%–12% compared to conventional pipeline pumps.
Energy-saving data: When pumping 50 m³/h of clear water with a head of 20 meters, the power consumption is only 7.5 kW—15% more energy-efficient than comparable products.
Stable operational performance
Low-vibration design: The axial force-balancing structure minimizes vibration, with noise levels ≤75 dB (measured at 1 meter), meeting the requirements of GB/T 10889 standard.
High resistance to cavitation: Required Net Positive Suction Head (NPSHr) ≤ 2.5 m, making it ideal for applications with high suction lift requirements.
Seamless operation
Wide-channel design: The channel width is ≥25mm, allowing smooth passage of impurities like fibers and particles, thereby reducing the risk of clogging.
Maintaining ease of use
Back-opening design: During maintenance, there’s no need to remove the piping—simply open the pump cover to replace components like the impeller and seals, reducing maintenance time by 60%.
Modular design: Standardization of components such as the pump body, impeller, and seals ensures high interchangeability of spare parts, reducing inventory costs.
Product Structure

Main performance parameters
| Model | Flow rate Q | Head height m | Efficiency % | Rotational speed r/min | Motor power KW | Necessary Cavitation Margin (NPSH)r (m) | |
| m³/h | l/s | ||||||
| 25-125 | 2.8 4.0 5.2 | 0.78 1.11 1.44 | 20.6 20.0 18.0 | 28 36 35 | 2900 | 0.75 | 2.3 |
| 25-125A | 2.5 3.6 4.6 | 0.69 1.00 1.28 | 17.0 16.0 14.4 | 35 | 2900 | 0.55 | 2.3 |
| 25-160 | 2.8 4 5.2 | 0.78 1.11 1.44 | 33 32 30 | 24 32 33 | 2900 | 1.5 | 2.3 |
| 25-160A | 2.6 3.7 4.9 | 0.12 1.03 1.36 | 29 28 26 | 31 | 2900 | 1.1 | 2.3 |
| 32-100(I) | 4.4 6.3 8.3 | 1.22 1.75 2.32 | 13.2 12.5 11.3 | 48 54 53 | 2900 | 0.75 | 2.0 |
| 32-125 | 3.5 5 6.5 | 0.97 1.39 1.8 | 22 20 18 | 40 44 42 | 2900 | 0.75 | 2.3 |
| 32-125A | 3.1 4.5 5.8 | 0.86 1.25 1.61 | 17.6 16 14.4 | 43 | 2900 | 0.55 | 2.3 |
| 32-160 | 3.5 4.5 6 | 0.97 1.25 1.67 | 33 32 30 | 30 35 33 | 2900 | 1.5 | 2.3 |
| 32-160A | 3.5 4.5 6 | 0.97 1.25 1.67 | 26.5 25 23 | 29 34 32 | 2900 | 1.1 | 2.3 |
| 32-200 | 3.5 4.5 5.5 | 0.97 1.25 1.53 | 51 50 48 | 27 32 30 | 2900 | 3 | 2.3 |
| 32-200A | 3.9 4 4.2 | 1.08 1.11 1.17 | 41 40 38 | 26 31 29 | 2900 | 2.2 | 2.3 |
| 40-100 | 4.4 6.3 8.3 | 1.22 1.75 2.31 | 13.2 12.5 11.3 | 48 54 53 | 2900 | 0.55 | 2.3 |
| 40-100A | 3.9 5.6 7.4 | 1.08 1.56 2.06 | 10.6 10 9 | 52 | 2900 | 0.37 | 2.3 |
| 40-125 | 4.4 6.3 8.3 | 1.22 1.75 2.31 | 21 20 18 | 41 46 43 | 2900 | 1.1 | 2.3 |
| 40-125A | 3.9 5.6 7.4 | 1.08 1.56 2.06 | 17.6 16 14.4 | 40 45 41 | 2900 | 0.75 | 2.3 |
| 40–160 | 4.4 6.3 8.3 | 1.22 1.75 2.31 | 33 32 30 | 35 40 40 | 2900 | 2.2 | 2.3 |
| 40-160A | 4.1 5.9 7.8 | 1.14 1.64 2.17 | 29 28 26.3 | 34 39 39 | 2900 | 1.5 | 2.3 |
| 40-160B | 3.8 5.5 7.2 | 1.06 1.53 2.0 | 25.5 24 22.5 | 34 38 37 | 2900 | 1.1 | 2.3 |
| 40-200 | 4.4 6.3 8.3 | 1.22 1.75 2.31 | 51 50 48 | 26 33 32 | 2900 | 4.0 | 2.3 |
| 40-200A | 4.1 5.9 7.8 | 1.14 1.64 2.17 | 45 44 42 | 26 31 30 | 2900 | 3.0 | 2.3 |
| 40-200B | 3.8 5.5 7.2 | 1.06 1.53 2.0 | 38 36 34.5 | 25 29 28 | 2900 | 2.2 | 2.3 |
| 40-250 | 4.4 6.3 8.3 | 1.22 1.75 2.31 | 82 80 74 | 24 28 28 | 2900 | 7.5 | 2.3 |
| 40-250A | 4.1 5.9 7.8 | 1.14 1.64 2.17 | 72 70 65 | 24 28 27 | 2900 | 5.5 | 2.3 |
| Model | Flow rate Q | Head height m | Efficiency % | Rotational speed r/min | Motor power KW | Necessary Cavitation Margin (NPSH)r (m) | |
| m³/h | l/s | ||||||
| 40-250B | 3.8 5.5 7.2 | 1.06 1.53 1.94 | 61.5 50 56 | 23 27 26 | 2900 | 4.0 | 2.3 |
| 40-100(I) | 8.8 12.5 16.3 | 2.44 3.47 4.53 | 13.2 12.5 11.3 | 55 62 60 | 2900 | 1.1 | 2.3 |
| 40–100 (I) A | 8 11 14.5 | 2.22 3.05 4.03 | 10.6 10 9 | 54 60 58 | 2900 | 0.75 | 2.3 |
| 40-125(I) | 8.8 12.5 16.3 | 2.44 3.47 4.53 | 21.2 20 17.8 | 49 58 57 | 2900 | 1.5 | 2.3 |
| 40-125(I)A | 8 11 14.5 | 2.22 3.05 4.03 | 17 16 14 | 48 57 56 | 2900 | 1.1 | 2.3 |
| 40-160(I) | 8.8 12.5 16.3 | 2.44 3.47 4.53 | 33 32 30 | 45 52 51 | 2900 | 3 | 2.3 |
| 40–160 (I)A | 8.2 11.7 15.2 | 2.28 3.25 4.22 | 29 28 26 | 44 51 50 | 2900 | 2.2 | 2.3 |
| 40-200(I) | 8.8 12.5 16.3 | 2.44 3.47 4.53 | 51.2 50 48 | 38 46 46 | 2900 | 5.5 | 2.3 |
| 40-200 (I)A | 8.3 11.7 15.3 | 2.31 3.25 4.25 | 45 44 42 | 47 45 45 | 2900 | 4 | 2.3 |
| 40-200(I)B | 7.5 10.5 13.8 | 2.08 2.92 3.83 | 37 36 34 | 36 44 44 | 2900 | 3 | 2.3 |
| 40-250(I) | 8.8 12.5 16.3 | 2.44 3.47 4.53 | 81.2 80 77.5 | 31 40 38 | 2900 | 11 | 2.3 |
| 40–250 (I)A | 8.2 11.7 15.2 | 2.28 3.25 4.22 | 71 70 68 | 30 38 36 | 2900 | 7.5 | 2.3 |
| 40-250(I)B | 7.5 10.5 13.8 | 2.08 2.92 3.83 | 61.4 50 58 | 29 37 35 | 2900 | 7.5 | 2.3 |
| 50–100 | 8.8 12.5 16.3 | 2.44 3.47 4.53 | 13.2 12.5 11.3 | 55 62 60 | 2900 | 1.1 | 2.3 |
| 50-100A | 8 11 14.5 | 2.22 3.05 4.03 | 10.6 10 9 | 54 60 58 | 2900 | 0.75 | 2.3 |
| 50-125 | 8.8 12.5 16.3 | 2.44 3.47 4.53 | 21.2 20 17.8 | 49 58 57 | 2900 | 1.5 | 2.3 |
| 50-125A | 8 11 14.5 | 2.22 3.05 4.03 | 17 16 14 | 48 57 56 | 2900 | 1.1 | 2.3 |
| 50-160 | 8.8 12.5 16.3 | 2.44 3.47 4.53 | 33 32 30 | 45 52 51 | 2900 | 3 | 2.3 |
| 50-160A | 8.2 11.7 15.2 | 2.28 3.25 4.22 | 29 28 26 | 44 51 50 | 2900 | 2.2 | 2.3 |
| 50-160B | 7.3 10.4 13.5 | 2.38 2.98 3.75 | 23 22 20.5 | 43 50 49 | 2900 | 1.5 | 2.3 |
| 50–200 | 8.8 12.5 16.3 | 2.44 3.47 4.53 | 51.2 50 48 | 38 46 46 | 2900 | 5.5 | 2.3 |
| 50-200A | 8.3 11.7 15.3 | 2.31 3.25 4.25 | 45 44 42 | 47 45 45 | 2900 | 4 | 2.3 |
| 50-200B | 7.5 10.5 13.8 | 2.08 2.92 3.83 | 37 36 34 | 36 44 44 | 2900 | 3 | 2.3 |
Zero
| Model | Flow rate Q | Head height m | Efficiency % | Rotational speed r/min | Motor power KW | Necessary Cavitation Margin (NPSH)r (m) | |
| m³/h | l/s | ||||||
| 50-250 | 8.8 12.5 16.3 | 2.44 3.47 4.53 | 81.2 80 77.5 | 31 40 38 | 2900 | 11 | 2.3 |
| 50-250A | 8.2 11.7 15.2 | 2.28 3.25 4.22 | 71 70 68 | 30 38 36 | 2900 | 7.5 | 2.3 |
| 50-250B | 7.5 10.5 13.8 | 2.08 2.92 3.83 | 61.4 50 58 | 29 37 35 | 2900 | 7.5 | 2.3 |
| 50–100 (I) | 17.5 25 32.5 | 4.86 6.94 9.03 | 13.7 12.5 10.5 | 67 69 69 | 2900 | 1.5 | 2.3 |
| 50-100 (I) A | 15.6 22.3 29 | 4.3 6.19 8.1 | 11 10 8.4 | 65 68 67 | 2900 | 1.1 | 2.3 |
| 50-125(I) | 17.5 25 32.5 | 4.86 6.94 9.032 | 21.5 20 18 | 60 68 67 | 2900 | 3 | 2.3 |
| 50–125 (I) A | 15.6 22.3 29 | 4.33 6.19 8.1 | 17 16 13.6 | 58 66 65 | 2900 | 2.2 | 2.3 |
| 50-160(I) | 17.5 25 32.5 | 4.86 6.94 9.03 | 34.4 32 27.5 | 54 65 62 | 2900 | 4 | 2.3 |
| 50–160 (I) A | 16.4 23.4 30.4 | 4.56 6.5 8.44 | 30 28 24 | 54 62 59 | 2900 | 4 | 2.3 |
| 50-160(I)B | 15 21.6 28 | 4.17 6 7.78 | 26 24 20.6 | 51 58 56 | 2900 | 3 | 2.5 |
| 50-200(I) | 17.5 25 32.5 | 4.86 6.94 9.03 | 52.7 50 45.5 | 53 60 58 | 2900 | 7.5 | 2.5 |
| 50–200 (I) A | 16.4 23.4 30.4 | 4.56 6.5 8.44 | 46.4 44 40 | 49 58 54 | 2900 | 7.5 | 2.5 |
| 50-200(I)B | 15 21.6 28 | 4.17 6 7.78 | 40 38 34.5 | 47 55 51 | 2900 | 5.5 | 2.5 |
| 50-250(I) | 17.5 25 32.5 | 4.86 6.94 9.03 | 82 80 76.2 | 49 52 50 | 2900 | 15 | 2.5 |
| 50–250 (I) A | 16.4 23.4 30.4 | 4.56 6.5 8.44 | 71.5 70 67 | 45 51 47 | 2900 | 11 | 2.5 |
| 50-250(I)B | 15 21.6 28 | 4.17 6 7.78 | 61 60 57.4 | 38 54 49 | 2900 | 11 | 2.5 |
| 50-315(I) | 17.5 25 32.5 | 4.86 6.94 9.03 | 128 125 122 | 38 44 40 | 2900 | 30 | 2.5 |
| 50-315(I)A | 16.4 23.4 30.4 | 4.56 6.5 8.44 | 115 113 112 | 37 43 40 | 2900 | 22 | 2.5 |
| 50-315(I)B | 15.7 22.5 29.2 | 4.36 6.25 8.1 | 103 101 98 | 33 39 37 | 2900 | 18.5 | 2.5 |
| 65–100 | 17.5 25 32.5 | 4.86 6.94 9.03 | 13.7 12.5 10.5 | 67 69 69 | 2900 | 1.5 | 2.5 |
| 65-100A | 15.6 22.3 29 | 4.3 6.19 8.1 | 11 10 8.4 | 65 68 67 | 2900 | 1.1 | 2.5 |
| 65-125 | 17.5 25 32.5 | 4.86 6.94 9.032 | 21.5 20 18 | 60 68 67 | 2900 | 3 | 2.5 |
| Model | Flow rate Q | Head height m | Efficiency % | Rotational speed r/min | Motor power KW | Necessary Cavitation Margin (NPSH)r | |
| m³/h | l/s | ||||||
| 65-125A | 15.6 22.3 29 | 4.33 6.19 8.1 | 17 16 13.6 | 58 66 65 | 2900 | 2.2 | 2.5 |
| 65-160 | 17.5 25 32.5 | 4.86 6.94 9.03 | 34.4 32 27.5 | 54 65 62 | 2900 | 4 | 2.5 |
| 65-160A | 16.4 23.4 30.4 | 4.56 6.5 8.44 | 30 28 24 | 54 62 59 | 2900 | 4 | 2.5 |
| 65-160B | 15 21.6 28 | 4.17 6 7.78 | 26 24 20.6 | 51 58 56 | 2900 | 3 | 2.5 |
| 65-200 | 17.5 25 32.5 | 4.86 6.94 9.03 | 52.7 50 45.5 | 53 60 58 | 2900 | 7.5 | 2.5 |
| 65-200A | 16.4 23.4 30.4 | 4.56 6.5 8.44 | 46.4 44 40 | 49 58 54 | 2900 | 7.5 | 2.5 |
| 65-200B | 15 21.6 28 | 4.17 6 7.78 | 40 38 34.5 | 47 55 51 | 2900 | 5.5 | 2.5 |
| 65-250 | 17.5 25 32.5 | 4.86 6.94 9.03 | 82 80 76.2 | 49 52 50 | 2900 | 15 | 2.5 |
| 65-250A | 16.4 23.4 30.4 | 4.56 6.5 8.44 | 71.5 70 67 | 45 51 47 | 2900 | 11 | 2.5 |
| 65-250B | 15 21.6 28 | 4.17 6 7.78 | 61 60 57.4 | 38 54 49 | 2900 | 11 | 2.5 |
| 65-315 | 17.5 25 32.5 | 4.86 6.94 9.03 | 128 125 122 | 38 44 40 | 2900 | 30 | 2.5 |
| 65-315A | 16.4 23.4 30.4 | 4.56 6.5 8.44 | 115 113 112 | 37 43 40 | 2900 | 22 | 2.5 |
| 65-315B | 15.7 22.5 29.2 | 4.36 6.25 8.1 | 103 101 98 | 33 39 37 | 2900 | 18.5 | 2.5 |
| 65-100(I) | 35 50 65 | 9.72 13.9 18.1 | 13.8 12.5 10 | 67 73 70 | 2900 | 3 | 3.0 |
| 65-100(I)A | 31.3 44.7 58 | 8.7 12.4 16.1 | 11 10 8 | 66 72 69 | 2900 | 2.2 | 3.0 |
| 65-125(I) | 35 50 65 | 9.72 13.9 18.1 | 22 20 17 | 67 72.5 70 | 2900 | 5.5 | 3.0 |
| 65-125(I)A | 31.3 45 58 | 8.7 12.5 16.1 | 17.5 16 13.6 | 66 71 69 | 2900 | 4 | 3.0 |
| 65-160(I) | 35 50 65 | 9.72 13.9 18.1 | 35 32 28 | 63 73 79 | 2900 | 7.5 | 3.0 |
| 65-160(I)A | 32.7 46.7 61 | 9.1 13.0 16.9 | 30.6 28 24 | 62 70 69 | 2900 | 7.5 | 3.0 |
| 65-160(I)B | 30.3 43.3 56.3 | 8.4 12 15.6 | 26 24 21 | 61 69 68 | 2900 | 5.5 | 3.0 |
| 65-200(I) | 35 50 65 | 9.72 13.9 18.1 | 53.5 50 46 | 55 69 67 | 2900 | 15 | 3.0 |
| 65-200 (I)A | 32.7 46.7 61 | 9.1 13.0 16.9 | 47 44 40 | 54 67 66 | 2900 | 11 | 3.0 |
| Model | Flow rate Q | Head height m | Efficiency % | Rotational speed r/min | Motor power KW | Necessary Cavitation Margin (NPSH)r (m) | |
| m³/h | l/s | ||||||
| 65-200(I)B | 30.3 43.3 56.3 | 8.4 12 15.6 | 40.6 36 33.4 | 53 65 64 | 2900 | 7.5 | 3.0 |
| 65-250(I) | 35 50 65 | 9.72 13.9 18.1 | 83 80 72 | 52 62 59 | 2900 | 22 | 3.0 |
| 65-250 (I)A | 32.7 46.7 61 | 9.1 13.0 16.9 | 73 70 63 | 58 60 58 | 2900 | 18.5 | 3.0 |
| 65-250(I)B | 30.3 43.3 56.3 | 8.4 12 15.6 | 62 60 54 | 56 58 57 | 2900 | 15 | 3.0 |
| 65-315(I) | 35 50 65 | 9.72 13.9 18.1 | 128 125 121 | 44 54 57 | 2900 | 37 | 3.0 |
| 65-315(I)A | 32.5 46.5 60.5 | 9.0 12.9 16.8 | 112.6 110 106.4 | 43 54 57 | 2900 | 30 | 3.0 |
| 65-315(I)B | 31 44.5 58 | 8.6 12.4 16.1 | 102.5 100 98 | 53 | 2900 | 30 | 3.0 |
| 65-315(I)C | 29 41 53.6 | 8.1 11.4 14.9 | 87 85 83 | 41 | 2900 | 22 | 3.0 |
| 80-100 | 35 50 65 | 9.72 13.9 18.1 | 13.8 12.5 10 | 67 73 70 | 2900 | 3 | 3.0 |
| 80-100A | 31.3 44.7 58 | 8.7 12.4 16.1 | 11 10 8 | 66 72 69 | 2900 | 2.2 | 3.0 |
| 80-125 | 35 50 65 | 9.72 13.9 18.1 | 22 20 17 | 67 72.5 70 | 2900 | 5.5 | 3.0 |
| 80-125A | 31.3 45 58 | 8.7 12.5 16.1 | 17.5 16 13.6 | 66 71 69 | 2900 | 4 | 3.0 |
| 80–160 | 35 50 65 | 9.72 13.9 18.1 | 35 32 28 | 63 73 79 | 2900 | 7.5 | 3.0 |
| 80-160A | 32.7 46.7 61 | 9.1 13.0 16.9 | 30.6 28 24 | 62 70 69 | 2900 | 7.5 | 3.0 |
| 80-160B | 30.3 43.3 56.3 | 8.4 12 15.6 | 26 24 21 | 61 69 68 | 2900 | 5.5 | 3.0 |
| 80-200 | 35 50 65 | 9.72 13.9 18.1 | 53.5 50 46 | 55 69 67 | 2900 | 15 | 3.0 |
| 80-200A | 32.7 46.7 61 | 9.1 13.0 16.9 | 47 44 40 | 54 67 66 | 2900 | 11 | 3.0 |
| 80-200B | 30.3 43.3 56.3 | 8.4 12 15.6 | 40.6 36 33.4 | 53 65 64 | 2900 | 7.5 | 3.0 |
| 80-250 | 35 50 65 | 9.72 13.9 18.1 | 83 80 72 | 52 62 59 | 2900 | 22 | 3.0 |
| 80-250A | 32.7 46.7 61 | 9.1 13.0 16.9 | 73 70 63 | 58 60 58 | 2900 | 18.5 | 3.0 |
| 80-250B | 30.3 43.3 56.3 | 8.4 12 15.6 | 62 60 54 | 56 58 57 | 2900 | 15 | 3.0 |
| Model | Flow rate Q | Head height m | Efficiency % | Rotational speed r/min | Motor power KW | Necessary Cavitation Margin (NPSH)r (m) | |
| m³/h | l/s | ||||||
| 80-315 | 35 50 65 | 9.72 13.9 18.1 | 128 125 121 | 44 54 57 | 2900 | 37 | 3.0 |
| 80-315A | 32.5 46.5 60.5 | 9.0 12.9 16.8 | 112.6 110 106.4 | 43 54 57 | 2900 | 30 | 3.0 |
| 80-315B | 31 44.5 58 | 8.6 12.4 16.1 | 102.5 100 98 | 53 | 2900 | 30 | 3.0 |
| 80-315C | 29 41 53.6 | 8.1 11.4 14.9 | 87 85 83 | 41 | 2900 | 22 | 3.0 |
| 80-350 | 35 50 60 | 9.72 13.9 16.7 | 156 150 140 | 53 54 52 | 2900 | 55 | 3.0 |
| 80-350A | 30.3 44 52.8 | 8.56 12.2 14.7 | 148 142 135 | 45 51 50 | 2900 | 45 | 3.0 |
| 80-350B | 28 40 46 | 7.78 11.1 12.8 | 142 135 128 | 39 48 46 | 2900 | 37 | 3.0 |
| 80-100 (I) | 70 100 130 | 19.4 27.8 36.1 | 14 12.5 11 | 66 76 75 | 2900 | 5.5 | 4.5 |
| 80-100 (I) A | 62.6 89 116 | 17.4 24.7 32.2 | 12 10 8.8 | 64 74 74 | 2900 | 4 | 4.5 |
| 80-125(I) | 70 100 130 | 19.4 27.8 36.1 | 23.5 20 14 | 70 76 72 | 2900 | 11 | 4.5 |
| 80-125 (I)A | 62.6 89 116 | 17.4 24.7 32.2 | 19 16 11 | 68 74 65 | 2900 | 7.5 | 4.5 |
| 80–160(I) | 70 100 130 | 19.4 27.8 36.1 | 36.5 32 24 | 70 76 65 | 2900 | 15 | 4.5 |
| 80-160 (I) A | 65.4 93.5 121 | 18.2 26 33.8 | 32 28 21 | 68 74 67 | 2900 | 11 | 4.5 |
| 80-160(I)B | 60.6 86.6 112 | 16.8 24.1 31.3 | 27 24 18 | 66 72 65 | 2900 | 11 | 4.5 |
| 80-200(I) | 70 100 130 | 19.4 27.8 36.1 | 54 50 42 | 65 74 73 | 2900 | 22 | 4.0 |
| 80-200 (I)A | 65.4 93.5 121 | 18.2 26 33.8 | 47.5 44 37 | 64 73 72 | 2900 | 18.5 | 4.0 |
| 80-200(I)B | 60.6 86.6 112 | 16.8 24.1 31.3 | 41 38 32 | 62 71 70 | 2900 | 15 | 4.0 |
| 80-250(I) | 70 100 130 | 19.4 27.8 36.1 | 87 80 68 | 62 71 68 | 2900 | 37 | 4.0 |
| 80–250 (I) A | 65.4 93.5 121 | 18.2 26 33.8 | 76 70 59.5 | 61 68 67 | 2900 | 30 | 4.0 |
| 80-250(I)B | 60.6 86.6 112 | 16.8 24.1 31.3 | 41 38 32 | 62 71 70 | 2900 | 22 | 4.0 |
| 80-315(I) | 70 100 130 | 19.4 27.8 36.1 | 132 125 114 | 55 57 66 | 2900 | 75 | 4.0 |
| Model | Flow rate Q | Head height m | Efficiency % | Rotational speed r/min | Motor power KW | Necessary Cavitation Margin (NPSH)r (m) | |
| m³/h | l/s | ||||||
| 80-315(I)A | 66.5 95 123 | 18.5 26.4 34.3 | 119 113 103 | 59 65 64 | 2900 | 55 | 4.0 |
| 80-315(I)B | 63 90 117 | 17.5 25 32.5 | 106 101 92 | 58 65 63 | 2900 | 45 | 4.0 |
| 80-315(I)C | 58 82 107 | 16.1 22.9 29.7 | 90 85 76 | 56 63 61 | 2900 | 37 | 4.0 |
| 100-100 | 70 100 130 | 19.4 27.8 36.1 | 14 12.5 11 | 66 76 75 | 2900 | 5.5 | 4.5 |
| 100-100A | 62.6 89 116 | 17.4 24.7 32.2 | 12 10 8.8 | 64 74 74 | 2900 | 4 | 4.5 |
| 100–125 | 70 100 130 | 19.4 27.8 36.1 | 23.5 20 14 | 70 76 72 | 2900 | 11 | 4.5 |
| 100-125A | 62.6 89 116 | 17.4 24.7 32.2 | 19 16 11 | 68 74 65 | 2900 | 7.5 | 4.5 |
| 100–160 | 70 100 130 | 19.4 27.8 36.1 | 36.5 32 24 | 70 76 65 | 2900 | 15 | 4.5 |
| 100-160A | 65.4 93.5 121 | 18.2 26 33.8 | 32 28 21 | 68 74 67 | 2900 | 11 | 4.5 |
| 100-160B | 60.6 86.6 112 | 16.8 24.1 31.3 | 27 24 18 | 66 72 65 | 2900 | 11 | 4.5 |
| 1000 - 200 | 70 100 130 | 19.4 27.8 36.1 | 54 50 42 | 65 74 73 | 2900 | 22 | 4.0 |
| 1000-200A | 65.4 93.5 121 | 18.2 26 33.8 | 47.5 44 37 | 64 73 72 | 2900 | 18.5 | 4.0 |
| 100-200B | 60.6 86.6 112 | 16.8 24.1 31.3 | 41 38 32 | 62 71 70 | 2900 | 15 | 4.0 |
| 100–250 | 70 100 130 | 19.4 27.8 36.1 | 87 80 68 | 62 71 68 | 2900 | 37 | 4.0 |
| 100-250A | 65.4 93.5 121 | 18.2 26 33.8 | 76 70 59.5 | 61 68 67 | 2900 | 30 | 4.0 |
| 100-250B | 60.6 86.6 112 | 16.8 24.1 31.3 | 41 38 32 | 62 71 70 | 2900 | 22 | 4.0 |
| 100-315 | 70 100 130 | 19.4 27.8 36.1 | 132 125 114 | 55 57 66 | 2900 | 75 | 4.0 |
| 100-315A | 66.5 95 123 | 18.5 26.4 34.3 | 119 113 103 | 59 65 64 | 2900 | 55 | 4.0 |
| 100-315B | 63 90 117 | 17.5 25 32.5 | 106 101 92 | 58 65 63 | 2900 | 45 | 4.0 |
| 100-315C | 58 82 107 | 16.1 22.9 29.7 | 90 85 76 | 56 63 61 | 2900 | 37 | 4.0 |
| 100–350 | 70 100 130 | 19.4 27.8 36.1 | 156 150 138 | 63 65 64 | 2900 | 90 | 4.0 |
| 100-350A | 64 88 113 | 17.8 14.4 31.4 | 148 142 134 | 60 63 62 | 2900 | 75 | 4.0 |
| Model | Flow rate Q | Head height m | Efficiency % | Rotational speed r/min | Motor power KW | Necessary Cavitation Margin (NPSH)r (m) | |
| m³/h | l/s | ||||||
| 100-350B | 56 80 104 | 15.6 22.2 28.9 | 140 135 125 | 55 60 69 | 2900 | 55 | 4.0 |
| 100-100(I) | 100 160 200 | 27.8 44.4 55.5 | 13 12.5 11 | 71 82 81 | 2900 | 11 | 4.0 |
| 100-125(I) | 100 160 200 | 27.8 44.4 55.5 | 22.5 20 17 | 70 80 80 | 2900 | 15 | 4.0 |
| 100-125(I)A | 88 143 176 | 24.4 39.7 48.9 | 18 16 13.6 | 67 70 72 | 2900 | 11 | 4.0 |
| 100-160(I) | 100 160 200 | 27.8 44.4 55.5 | 35 32 28 | 66 78 76 | 2900 | 22 | 4.0 |
| 100–160 (I) A | 93.5 150 187 | 26 41.7 51.9 | 31 28 24.5 | 65 76 75 | 2900 | 18.5 | 4.0 |
| 100-200(I) | 100 160 200 | 27.8 44.4 55.5 | 54 50 46 | 65 77 75 | 2900 | 37 | 4.0 |
| 100–200 (I) A | 93.5 150 187 | 26 41.7 51.9 | 47.5 44 40.5 | 64 76 75 | 2900 | 30 | 4.0 |
| 100–200 (I)B | 85 138 170 | 23.6 28.3 47.2 | 40 37 34 | 63 75 75 | 2900 | 22 | 4.0 |
| 100-250(I) | 100 160 200 | 27.8 44.4 55.5 | 86 80 73 | 62 75 74 | 2900 | 55 | 4.0 |
| 100–250 (I) A | 93.5 150 187 | 26 41.7 51.9 | 75 70 64 | 62 74 73 | 2900 | 45 | 4.0 |
| 100-250(I)B | 85 138 170 | 23.6 28.3 47.2 | 64 60 55 | 62 73 72 | 2900 | 37 | 4.0 |
| 125-100 | 100 160 200 | 27.8 44.4 55.5 | 13 12.5 11 | 71 82 81 | 2900 | 11 | 4.0 |
| 125-100A | 100 143 172 | 27.8 39.7 47.8 | 12 10 8.5 | 77 | 2900 | 7.5 | 4.0 |
| 125-125 | 100 160 200 | 27.8 44.4 55.5 | 22.5 20 17 | 70 80 80 | 2900 | 15 | 4.0 |
| 125-125A | 88 143 176 | 24.4 39.7 48.9 | 18 16 13.6 | 67 70 72 | 2900 | 11 | 4.0 |
| 125–160 | 100 160 200 | 27.8 44.4 55.5 | 35 32 28 | 66 78 76 | 2900 | 22 | 4.0 |
| 125-160A | 93.5 150 187 | 26 41.7 51.9 | 31 28 24.5 | 65 76 75 | 2900 | 18.5 | 4.0 |
| 125-160B | 83 138 166 | 21.7 38.3446.1 | 27 24 21 | 43 | 2900 | 15 | 4.0 |
| 125-200 | 100 160 200 | 27.8 44.4 55.5 | 54 50 46 | 65 77 75 | 2900 | 37 | 4.0 |
| 125-200A | 90 150 180 | 25 41.7 50 | 48.4 44 40.5 | 76 | 2900 | 30 | 4.0 |
| 125-200B | 83 138 166 | 21.7 38.3446.1 | 41.3 37.5 34.5 | 75 | 2900 | 22 | 4.0 |
| Model | Flow rate Q | Head height m | Efficiency % | Rotational speed r/min | Motor power KW | Necessary Cavitation Margin (NPSH)r (m) | |
| m³/h | l/s | ||||||
| 125-250 | 96 160 192 | 26.7 44.4 55.3 | 86 80 73 | 62 75 74 | 2900 | 55 | 4.0 |
| 125-250A | 90 150 180 | 25 41.7 50 | 75 70 64 | 62 74 73 | 2900 | 45 | 4.0 |
| 125-250B | 86 143 172 | 23.9 39.7447.8 | 64 60 55 | 62 73 72 | 2900 | 37 | 4.0 |
| 125-315 | 96 160 192 | 26.7 44.4 55.3 | 133 125 119 | 70 | 2900 | 90 | 4.0 |
| 125-315A | 90 150 180 | 25 41.7 50 | 117 110 104 | 70 | 2900 | 75 | 4.0 |
| 125-315B | 86 143 172 | 23.9 39.7447.8 | 106 100 95.2 | 69 | 2900 | 75 | 4.0 |
| 125-315C | 80.5 134 161 | 22.4 37.2 44.7 | 96 88 86 | 67 | 2900 | 55 | 4.0 |
| 150-125 | 112 160 192 | 31.1 44.4 53.3 | 22.8 20 17 | 72 80 76 | 2900 | 15 | 4.0 |
| 150-125A | 105 150 180 | 29.2 41.7 50 | 31.5 28 24.5 | 71 76 73 | 2900 | 11 | 4.0 |
| 150–160 | 112 160 192 | 31.1 44.4 53.3 | 35 32 28 | 72 78 76 | 2900 | 22 | 4.0 |
| 150-160A | 105 150 180 | 29.2 41.7 50 | 31.5 28 24.5 | 71 76 73 | 2900 | 18.5 | 4.0 |
| 150-160B | 98 140 168 | 27.2 38.9 46.7 | 27 24 21 | 67 73 72 | 2900 | 15 | 4.0 |
| 150–200 | 96 160 192 | 26.7 44.4 55.3 | 55 50 46 | 77 | 2900 | 37 | 4.0 |
| 150-200A | 90 150 180 | 25 41.7 50 | 48.444 40.5 | 76 | 2900 | 30 | 4.0 |
| 150-200B | 86 143 172 | 23.9 39.7447.8 | 41.3 37.5 34.5 | 75 | 2900 | 22 | 4.0 |
| 150–250 | 120 200 240 | 33.3 55.6 66.7 | 87 80 72 | 65 76 74 | 2900 | 75 | 4.0 |
| 150-250A | 112 187 224 | 31.1 51.9 62.2 | 76 70 63 | 64 75 73 | 2900 | 55 | 4.0 |
| 150-250B | 104 173 208 | 26.9 48.1 57.8 | 65 60 54 | 63 74 72 | 2900 | 45 | 4.0 |
| 150-315 | 120 200 240 | 33.3 55.6 66.7 | 133 125 120 | 58 75 73 | 2900 | 110 | 4.5 |
| 150-315A | 112 187 224 | 31.1 51.9 62.2 | 116 110 105 | 57 74 72 | 2900 | 90 | 4.5 |
| 150-315B | 104 173 208 | 26.9 48.1 57.8 | 100 95 91 | 55 72 70 | 2900 | 75 | 4.5 |
| 150–350 | 112 160 192 | 31.1 44.4 53.3 | 160 150 138 | 69 70 67 | 2900 | 110 | 4.5 |
| Model | Flow rate Q | Head height m | Efficiency % | Rotational speed r/min | Motor power KW | Necessary Cavitation Margin (NPSH)r (m) | |
| m³/h | l/s | ||||||
| 150-350A | 105 150 180 | 29.2 41.7 50 | 152 142 130 | 689 69 65 | 2900 | 90 | 4.5 |
| 150-350B | 98 140 168 | 27.2 38.9 46.7 | 110 101 90 | 63 67 60 | 2900 | 75 | 4.5 |
| 150–400 | 140 200 260 | 38.9 55.6 72.2 | 53 50 44 | 68 75 71 | 1450 | 45 | 3.5 |
| 150-400A | 131 187 243 | 36.4 51.9 67.5 | 46.4 44 38.3 | 67 74 70 | 1450 | 37 | 3.5 |
| 150-400B | 122 174 226.5 | 33.9 48.3 62.9 | 40 38 33 | 73 | 1450 | 30 | 3.5 |
| 150-400C | 112 160 208 | 31.1 44.4 57.8 | 34 32 28 | 71 | 1450 | 22 | 3.5 |
| 150–200 (I) | 100 160 200 | 27.8 44.4 55.5 | 22.5 20 17 | 70 80 80 | 1450 | 15 | 3.0 |
| 150–200 (I) A | 88 143 176 | 24.4 39.7 48.9 | 18 16 13.6 | 67 70 72 | 1450 | 11 | 3.0 |
| 150-250(I) | 100 160 200 | 27.8 44.4 55.5 | 35 32 28 | 66 78 76 | 1450 | 22 | 3.0 |
| 150–250 (I) A | 93.5 150 187 | 26 41.7 51.9 | 31 28 24.5 | 65 76 75 | 1450 | 18.5 | 3.0 |
| 150-250(I)B | 100 160 200 | 27.8 44.4 55.5 | 54 50 46 | 65 77 75 | 1450 | 37 | 3.0 |
| 150-315(I) | 140 200 260 | 38.9 55.6 72.2 | 33.8 32 28 | 70 78 73 | 1450 | 30 | 3.5 |
| 150-315(I)A | 131 187 243 | 36.4 51.9 67.5 | 29.5 28 24.5 | 69 77 77 | 1450 | 22 | 3.5 |
| 150-315(I)B | 122 174 226.5 | 33.9 48.3 62.9 | 25 24 21 | 69 76 75 | 1450 | 18.5 | 3.5 |
| 200-200 | 140 200 260 | 38.9 55.6 72.2 | 13.8 12.5 10.6 | 67 78 78 | 1450 | 15 | 3.0 |
| 200-200A | 125 179 232 | 34.7 49.7 64.6 | 11 10 8.5 | 66 76 76 | 1450 | 11 | 3.0 |
| 200–250 | 140 200 260 | 38.9 55.6 72.2 | 21.8 20 17 | 73 80 77 | 1450 | 18.5 | 3.0 |
| 200-250A | 129 184 240 | 35.8 51.2 66.7 | 18.5 17 14.4 | 72 78 76 | 1450 | 15 | 3.0 |
| 200-250B | 117 167 217 | 32.5 46.4 60.4 | 15.2 14 12 | 70 76 75 | 1450 | 11 | 3.0 |
| 200-315 | 140 200 260 | 38.9 55.6 72.2 | 33.8 32 28 | 70 78 78 | 1450 | 30 | 3.5 |
| 200-315A | 131 187 243 | 36.4 51.9 67.5 | 29.5 28 24.5 | 69 77 77 | 1450 | 22 | 3.5 |
| 200-315B | 121 173 225 | 33.6 48.1 62.5 | 25.5 24 20.5 | 69 76 75 | 1450 | 18.5 | 3.5 |
| Model | Flow rate Q | Head height m | Efficiency % | Rotational speed r/min | Motor power KW | Necessary Cavitation Margin (NPSH)r (m) | |
| m³/h | l/s | ||||||
| 200–400 | 140 200 260 | 38.9 55.6 72.2 | 53 50 46 | 68 75 71 | 1450 | 45 | 3.5 |
| 200-400A | 131 187 243 | 36.4 51.9 67.5 | 46.6 44 38.3 | 67 74 70 | 1450 | 37 | 3.5 |
| 200-400B | 121 173 225 | 33.6 48.1 62.5 | 40 38 33 | 64 73 70 | 1450 | 30 | 3.5 |
| 200-400C | 112 160 208 | 31.3 44.4 57.8 | 34 32 28 | 64 71 69 | 1450 | 22 | 3.5 |
| 200-200(I) | 280 400 520 | 77.8 114 144 | 13.4 12.5 10.5 | 70 80 19 | 1450 | 22 | 3.5 |
| 200-200(I)A | 250 358 465 | 69.4 99.4 129 | 11.2 10 8.5 | 68 78 77 | 1450 | 18.5 | 4.0 |
| 200–250 (I) | 280 400 520 | 77.8 114 144 | 22.2 20 14 | 75 80 72 | 1450 | 30 | 4.0 |
| 200–250 (I) A | 250 358 465 | 69.4 99.4 129 | 18 16 11.2 | 14.4 13 9.3 | 1450 | 22 | 4.0 |
| 200–250 (I)B | 226 322 419 | 62.8 89.4 116 | 14.4 13 9.3 | 70 75 67 | 1450 | 18.5 | 4.0 |
| 200-315(I) | 280 400 520 | 77.8 114 144 | 36 32 26 | 73 80 75 | 1450 | 55 | 4.0 |
| 200-315(I)A | 262 374 486 | 72.8 103 135 | 31.5 28 23 | 72 79 74 | 1450 | 45 | 4.0 |
| 200-315(I)B | 242 346 450 | 67.2 96.1 125 | 27 24 19.5 | 71 78 73 | 1450 | 37 | 4.0 |
| 200–400 (I) | 280 400 520 | 77.8 114 144 | 54.5 50 39 | 75 81 77 | 1450 | 90 | 4.0 |
| 200–400 (I) A | 262 374 486 | 72.8 103 135 | 48 44 34 | 74 80 76 | 1450 | 75 | 4.0 |
| 200–400 (I)B | 242 346 450 | 67.2 96.1 125 | 41.4 38 29.6 | 72 78 74 | 1450 | 55 | 5.0 |
| 200–400°C | 224 320 416 | 62.2 88.9 115 | 34.9 32 25 | 70 76 72 | 1450 | 45 | 5.0 |
| 250-250 | 400 550 670 | 111.1 152.8 186.7 | 22.2 20 16 | 78 82 81 | 1450 | 45 | 5.0 |
| 250-250A | 365 500 600 | 101.4 138.9 166.7 | 19 17 14 | 76 80 80 | 1450 | 37 | 5.0 |
| 250–315 | 400 550 670 | 111.1 152.8 186.7 | 36 32 26 | 77 82 84 | 1450 | 75 | 5.0 |
| 250-315A | 365 500 600 | 101.4 138.9 166.7 | 31.5 28 23 | 76 80 82 | 1450 | 55 | 5.0 |
| 250-315B | 325 450 530 | 90.3 125 147.2 | 25 24 20 | 74 78 49 | 1450 | 45 | 5.0 |
| 250–400 | 400 550 670 | 111.1 152.8 186.7 | 54.5 50 39 | 75 78 80 | 1450 | 110 | 5.0 |
| Model | Flow rate Q | Head height m | Efficiency % | Rotational speed r/min | Motor power KW | Necessary Cavitation Margin (NPSH)r (m) | |
| m³/h | l/s | ||||||
| 250-400A | 365 500 600 | 101.4 138.9 166.7 | 47 44 35 | 74 77 79 | 1450 | 90 | 5.0 |
| 250-400B | 325 450 530 | 90.3 125 147.2 | 41.2 38 34.2 | 73 76 78 | 1450 | 75 | 5.0 |
| 300-300 | 480 720 900 | 133.3 200 250 | 31 28 25 | 77 81 77 | 1450 | 75 | 5.0 |
| 300-300A | 444 666 833 | 123.2 185 231.4 | 26.5 24 21.5 | 76 80 76 | 1450 | 55 | 5.0 |
| 300-300B | 415 623 779 | 115.3 173.1 216.4 | 23 21 18.5 | 79 | 1450 | 55 | 5.0 |
| 300–315 | 540 720 900 | 150 200 250 | 35 32 26 | 76 84 80 | 1450 | 90 | 5.0 |
| 300-315A | 460 650 800 | 127.8 180 222 | 31.5 28 23.5 | 72 80 77 | 1450 | 75 | 5.0 |
| 300-315B | 420 580 700 | 116.7 161 194 | 27 24 20 | 71 78 76 | 1450 | 55 | 5.0 |
| 300–400 | 500 720 900 | 138.9 200 250 | 54.5 50 42 | 80 | 1450 | 132 | 5.0 |
| 300-400A | 420 600 780 | 127.8 180.6233.3 | 47 44 37 | 78 | 1450 | 110 | 5.0 |
| 300–500 | 540 720 900 | 150 200 250 | 85 80 70 | 78 80 78 | 1450 | 250 | 5.5 |
| 300-500A | 506 675 720 | 140.6 187.5 200 | 74.4 70 61.2 | 77 79 77 | 1450 | 200 | 5.5 |
| 300-500B | 468 625 667 | 130 173.6 185.3 | 63.8 60 52.5 | 76 78 76 | 1450 | 160 | 5.5 |
| 300-500C | 425 570 605 | 118 158.3 168 | 53.2 50 43.8 | 75 77 75 | 1450 | 110 | 5.5 |
| 350-250 | 480 800 960 | 133.3 222 267 | 23 20 17.5 | 79 82 71 | 1450 | 75 | 5.0 |
| 350-250A | 430 715 860 | 199.4 198.6 238.9 | 18.5 16 13 | 81 | 1450 | 55 | 5.0 |
| 350-315 | 480 800 960 | 133.3 222 267 | 35 32 27 | 75 81 80 | 1450 | 90 | 5.0 |
| 350-315A | 450 749 900 | 125 207.8 250 | 30.5 28 23.5 | 80 | 1450 | 75 | 5.0 |
| 350-315B | 416 692 832 | 115.6 192.2 231.1 | 26 24 20 | 78 | 1450 | 75 | 5.0 |
| 350–400 | 480 800 960 | 133.3 222 267 | 55 50 46 | 76 82 80 | 1450 | 160 | 5.0 |
| 350-400A | 450 749 900 | 125 207.8 250 | 48 44 50 | 80 | 1450 | 132 | 5.0 |
| 350-400B | 416 692 832 | 115.6 192.2 231.1 | 42 38 34.5 | 78 | 1450 | 110 | 5.0 |
Product Showcase
![]() | ![]() | ![]() |
Industry Applications
![]() | ![]() | ![]() |
| Vertical pipeline and horizontal direct-coupled centrifugal pumps are suitable for municipal water supply and drainage, high-pressure building water boosting, fire protection boosting, and landscape irrigation, among other applications. | Vertical pipeline and horizontal direct-drive centrifugal pumps are suitable for long-distance transportation, HVAC and refrigeration systems, bathroom applications—including boosting water circulation for heating and cooling—as well as equipment integration. Operating temperature: up to 80°C. | Vertical pipeline and horizontal direct-connected hot water (high-temperature) circulation pumps are suitable for use in industries such as energy, metallurgy, chemical engineering, textiles, and papermaking. |
![]() | ![]() | ![]() |
| Vertical pipeline and horizontal direct-connected hot water (high-temperature) circulation pumps are suitable for boosting and circulating high-temperature boiler water, as well as for use in urban heating systems. The hot water can be used at temperatures up to T < 120°C. | Vertical pipeline and horizontal direct-coupled chemical pumps are suitable for industries such as petroleum, chemical processing, metallurgy, power generation, papermaking, food & pharmaceuticals, and synthetic fibers, with operating temperatures ranging from -20°C to +120°C. | Vertical pipeline and horizontal direct-drive oil pumps are suitable for conveying petroleum products such as gasoline, kerosene, and diesel, with operating temperatures ranging from 20°C to +120°C. |
Next episode