HainingAgricultural Flood Control Emergency Pump

The mobile flood-control pump truck is a specialized emergency response device integrating high-capacity drainage, rapid deployment, and intelligent control. It features quick response, efficient water removal, and all-weather operational capabilities.

Product Description

Performance parameters

Model Specifications Flow rate (m³/h) Head (m) Power (kW) Diesel engine model
YDBZ125-120-20 120 20 30.1 K4100D
YDBZ150-200-15 200 15 30.1 K4100D
YDBZ150-200-20 200 20 30.1 K4100D
YDBZ150-200-30 200 30 62 R4105AZD
YDBZ150-200-40 200 40 92 R6105AZD
YDBZ200-300-15 300 15 30.1 K4100D
YDBZ200-300-20 300 20 30.1 K4100D
YDBZ200-300-30 300 30 92 R6105AZD
YDBZ250-500-20 500 20 92 R6105AZD
YDBZ300-800-15 800 15 92 R6105AZD
YDBZ300-1000-15 1000 15 92 R6105AZD
YDBZ300-1200-15 1200 15 92 R6105AZD

Operating Steps

1. Connect the 50-meter-long water hose to the outlet. If the hose has an inner diameter that’s too small, first wrap plastic film around the outside of the outlet before attaching the hose. Secure the hose tightly on the outside using four clamps to prevent it from slipping off or leaking air.
2. If, after the diesel engine has been running at high speed for about 15 minutes, no water still flows into the inlet pipe, check the inlet pipe connections for any leaks and tighten the steel clamps securely. If there’s still no water flow, carefully inspect the outlet pipe installed afterward to ensure there are no leaks. After extending the outlet pipe by approximately 6 meters, coil up the remaining section—making sure no air enters the inlet opening. Next, use a vacuum pump to remove air from inside the water pump, followed by employing a vacuum-assisted device to draw water through the system.

3. Steps for using a gasoline-engine vacuum pump:
(1) Fill the gasoline engine fuel tank with gasoline, check the oil level in the gasoline engine, add water to the water tank above the vacuum pump unit, and fill the tank halfway with water.
(2) Place the throttle valve of the gasoline engine in the closed position:
(3) Turn on the fuel tank switch;
(4) Set the throttle to the low-speed position;
(5) Move the throttle plate to the low-speed position on the right side:
(6.) After starting, turn the fuel valve to the highway position, which means pulling the accelerator lever to the left:
(7) Open the vacuum pump valve located to the right of the pump outlet and parallel to the water pipe;
(8) Adjust the middle exhaust valve to the proper position on the right side! Start the vacuum pump and continue operating it until water is drawn out of the vacuum tube connected to the water pump, then start the large diesel engine.
(9) After evacuating the system, you’ll notice water flowing from the pump into the tank located above the vacuum pump. At this point, close the large pump’s exhaust valve! Then, turn the red switch on the right side of the gasoline engine to the OFF position.
(10.) The throttle must be closed to prevent oil leakage;
(11) After winter use, be sure to drain the water from both the large pump and the vacuum pump. Disconnect the small hose of the vacuum pump and thoroughly empty all water remaining inside! Additionally, if the battery’s negative terminal cable isn’t removed for an extended period, take precautions to prevent the battery from running flat.

The mobile flood-control pump truck is a specialized emergency response equipment integrating high-capacity drainage, rapid deployment, and intelligent control. It features quick response, efficient water removal, and all-weather operational capabilities.

Typical Performance Parameters

Parameters Lightweight Medium-sized Heavyweight
Discharge rate (m³/h) 300–800 800–2000 2000–5000
Head (m) 10-15 15-25 25-50
Suction lift (m) 6-7 5-6 (with self-priming) Vacuum-assisted required
Power (kW) 30–100 100–300 300–800
Through the particles ≤30mm ≤50mm ≤80mm

Product Features

Rapid Docking System: Hydraulic Automatic Docking for Suction Hose (Deployment Time ≤ 10 Minutes)

Self-protection features: Automatic shutdown upon water level overlimit, and abnormal oil temperature alarm.

Multi-modal drainage:

Self-priming mode (7m suction lift)

Dive mode (maximum depth of 20m)

Series Mode (Head Doubling)

Emergency Power Supply: Capable of delivering 380V/100kW of electricity for emergency rescue operations.

Silt-accumulation prevention design: Backwash system prevents pump blockage